2018 February New VMware 2V0-602 Exam Dumps with PDF and VCE Free Updated Today! Following are some new 2V0-602 Real Exam Questions:
1.|2018 New 2V0-602 Exam Dumps (PDF & VCE) 313Q&As Download:
https://www.braindump2go.com/2v0-602.html
2.|2018 New 2V0-602 Exam Questions & Answers Download:
https://drive.google.com/drive/folders/0B75b5xYLjSSNQnZDZHlKOU5xWm8?usp=sharing
QUESTION 298
ESXi 6.x can be installed upon which three supported hardware configurations? (Choose three.)
A. Local disk connected through Serial ATA (SATA)
B. Intel NX/XD disabled for the CPU in the system BIOS
C. 1 GbE network adapter
D. 2 GB of physical RAM
E. Intel NX/XD enabled for the CPU in the system BIOS
Answer: ACE
Explanation:
https://docs.vmware.com/en/VMware-vSphere/6.0/com.vmware.vsphere.install.doc/GUID-DEB8086A-306B-4239-BF76-E354679202FC.html
QUESTION 299
VM Components Protection (VMCP) can provide automated recovery for which two virtual machine failures? (Choose two.)
A. All Paths Down
B. Permanent Device Loss
C. Firmware failures
D. Driver Failures
Answer: AB
Explanation:
https://docs.vmware.com/en/VMware-vSphere/6.0/com.vmware.vsphere.avail.doc/GUID-F01F7EB8-FF9D-45E2-A093-5F56A788D027.html
QUESTION 300
Which two choices are valid ways to patch an ESXi host? (Choose two.)
A. Utilizing the esxcli Command Line Interface
B. Configuring a Host Profile
C. vRealize Operations Manager
D. vSphere Update Manager
Answer: AD
QUESTION 301
What are two valid iSCSI discovery methods? (Choose two.)
A. Assigned Discovery
B. Automatic Discovery
C. Static Discovery
D. LUN Masking
E. Dynamic Discovery
Answer: CE
Explanation:
https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.storage.doc/GUID-66215AF3-2D81-4D1F-92D4-B9623FC1CB0E.html
QUESTION 302
A vCenter Server displays this error for a single host:
Virtual machine creation may fail because agent is unable to retrieve VM creation options from the host
Which action will allow a vSphere Administrator to resolve the issue?
A. Log in to the vSphere Web Client, select the ESXi host and manually place it into Quarantine Mode.
B. Log in to the vCenter Server Appliance Management UI and reboot the VCSA.
C. Log in to the vSphere Web Client, select the cluster that the ESXi host belongs to and turn off DRS.
D. Log in to the host DCUI, press F2 and navigate to Troubleshooting Options> Restart management Agents.
Answer: D
Explanation:
https://kb.vmware.com/s/article/1003490
QUESTION 303
Which option is true during a virtual machine cold migration?
A. Data is transferred over the vMotion VMKernel interface.
B. The datastore of the virtual machine cannot be changed.
C. Migrating a virtual machine from an Intel-based host to a AMD-based host generates an error.
D. Migrating a 64-bit virtual machine to a 32-bit host generates a warning.
Answer: D
Explanation:
https://docs.vmware.com/en/VMware-vSphere/6.0/com.vmware.vsphere.vcenterhost.doc/ GUID-98C18721-A4B0-4BD2-96BF-1BBC29391B3E.html
QUESTION 304
A vSphere Administrator notices that one of the virtual machines has been configured for VMDirectPath I/ O, and a physical NIC has been assigned to the VM.
What feature is not available to this VM?
A. Storage DRS
B. VMware Tools upgrades
C. vMotion
D. Virtual Machine Compatibility version upgrades
Answer: C
QUESTION 305
A VMware vSphere 6.x Administrator has been tasked with enabling the Integrated Load Balancer for the new vRealize Log Insight cluster.
What three options are required before the Integrated Load Balancer can be used? (Choose three.)
A. The time on the vRealize Log Insight virtual appliance must be synchronized with an NTP server.
B. All vRealize Log Insight nodes are configured as the same size.
C. The vRealize Log Insight master and work nodes must have CA signed certificates.
D. Verify that all vRealize Log Insight nodes and the specified Integrated Load Balancer IP address are on the same network.
E. The vRealize Log Insight master and worker nodes must have the same certificates.
Answer: ACD
Explanation:
http://pubs.vmware.com/log-insight-33/index.jsp?topic=%2Fcom.vmware.log-insight.administration.doc%2FGUID-72CB469A-F276-438D-BC93-77853E2CC0B9.html
QUESTION 306
A vSphere Administrator attempts to remove a host from a vSphere distributed switch, and fails. There is a notification that resources are still in use.
What are two possible causes? (Choose two.)
A. There are virtual machine network adapters connected to the distributed switch.
B. There are VMkernel adapters on the distributed switch that are in use.
C. The administrator does not have sufficient rights to remove the host from the distributed switch.
D. The ESXi host has a virtual machine with over 256 GB RAM assigned.
Answer: AB
Explanation:
https://docs.vmware.com/en/VMware-vSphere/6.0/com.vmware.vsphere.troubleshooting.doc/GUID-038AC93F-D710-48ED-8E3B-258A23FB2930.html
QUESTION 307
A vSphere Administrator wants to migrate a virtual machine from a host with an AMD Opteron CPU to an intel Xeon CPU.
Which method should be used?
A. Storage vMotion
B. vMotion
C. Cold Migration
D. Hot Migration
Answer: C
Explanation:
https://kb.vmware.com/s/article/1005764#Does%20EVC%20allow%20AMD%20and%20Intel%20CPUs%20to%20be%20vMotion%20compatible
QUESTION 308
A vSphere Administrator has stated that currently Private VLAN is utilized to prevent cross-talk on the dedicated backup network.
What two actions are required to implement Private VLAN in VMware vSphere? (Choose two.)
A. Configure Private VLAN at the dvPort Group.
B. Upgrade to VMware vSphere Enterprise Plus.
C. Enable Promiscuous Mode.
D. Configure Private VLAN at the dvSwitch level.
Answer: AC
QUESTION 309
What are two valid states for Compliance Status in VM Storage Policy? (Choose two.)
A. Compliant
B. Orphaned
C. Invalid
D. Out of Date
Answer: AD
Explanation:
https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.storage.doc/GUID-133B65D0-CE10-45E7-BFA5-74CAD19E0DFD.html
QUESTION 310
A VMware vSphere 6.x Administrator is looking at the following output from esxtop on an ESXi host:
What does DAVG/cmd represent?
A. Average device latency per command in milliseconds
B. Average ESXi VMkernel latency per command in milliseconds
C. Average queue latency per command in milliseconds
D. Average guest operating system latency per command in milliseconds.
Answer: A
QUESTION 311
Which two statements are Datastore Cluster requirements? (Choose two.)
A. Datastore clusters can only contain VMFS datastores.
B. Datastores shared across multiple data centers cannot be included in a datastore cluster.
C. NFS and VMFS datastores cannot cannot be combined in the same datastore cluster.
D. Datastore clusters must contain three or more datastores.
Answer: BC
Explanation:
https://pubs.vmware.com/vsphere-51/index.jsp?topic=%2Fcom.vmware.vsphere.resmgmt.doc%2FGUID-34A10B42-C79E-491C-A5AA-99E3B5FA2278.html
QUESTION 312
A vSphere Administrator just finished installing new software on the Windows vCenter Server and notices that vCenter Server services no longer start properly.
What two tasks should be done next? (Choose two.)
A. Contact the server hardware manufacturer.
B. Check for network port conflicts.
C. Reinstall vCenter Server.
D. Check the vCenter Server logs.
Answer: BD
QUESTION 313
A vSphere Administrator wants to enable Storage I/O Control. There is a mix of VMFS and NFS datastores. All of the VMFS datastores have hardware acceleration enabled. The Administrator attempts to create a new datastore cluster but is unable to add all of the datastores to the cluster.
What is the problem?
A. NFS datastores can not participate in a datastore cluster.
B. One of the hosts is currently in maintenance mode.
C. NFS and VMFS datastores cannot be mixed in a datastore cluster.
D. Datastores with hardware acceleration enabled can not participate in a datastore cluster.
Answer: C
Explanation:
https://docs.vmware.com/en/VMware-vSphere/6.5/com.vmware.vsphere.resmgmt.doc/GUID-34A10B42-C79E-491C-A5AA-99E3B5FA2278.html
!!!RECOMMEND!!!
1.|2018 New 2V0-602 Exam Dumps (PDF & VCE) 313Q&As Download:
https://www.braindump2go.com/2v0-602.html
2.|2018 New 2V0-602 Study Guide Video:
https://youtu.be/yqQaSdzIVk0
Braindump2go | Testking | Pass4sure | Actualtests | Others | |
$99.99 | $124.99 | $125.99 | $189 | $29.99/$49.99 | |
Up-to-Dated | ✔ | ✖ | ✖ | ✖ | ✖ |
Real Questions | ✔ | ✖ | ✖ | ✖ | ✖ |
Error Correction | ✔ | ✖ | ✖ | ✖ | ✖ |
Printable PDF | ✔ | ✖ | ✖ | ✖ | ✖ |
Premium VCE | ✔ | ✖ | ✖ | ✖ | ✖ |
VCE Simulator | ✔ | ✖ | ✖ | ✖ | ✖ |
One Time Purchase | ✔ | ✖ | ✖ | ✖ | ✖ |
Instant Download | ✔ | ✖ | ✖ | ✖ | ✖ |
Unlimited Install | ✔ | ✖ | ✖ | ✖ | ✖ |
100% Pass Guarantee | ✔ | ✖ | ✖ | ✖ | ✖ |
100% Money Back | ✔ | ✖ | ✖ | ✖ | ✖ |